Hi,

 

We have one new upgraded system at EHP6, earlier system was at EH4 where multiple user can Run one Z  T-code and can edit the entries for the Z-table.

This Z-Tcode is calling SM30 internally for updating the Z-Table.

Now in the upgraded system, when one user is into the transation code, and other user runs that T-code, systems throws a POP-UP mesg saying that the data is locked and can be displayed only(can not be edited).

I have debugged the code in both the environment and found that there is one statement Call C_ENQUEUE ID < > field. for which the Sy_Subrc is coming as 2 in the upgraded system which is causing the issue, where as the sy-subrc is 0 in the system at EH4 level.

Can any body tell me why this Z-tcode is not allowing to be accessed by multiple user at same time for Editing(updating the table) .

 

Regards,

Archana Jha